Deskripsi Singkat :
Jual Multimerter merk FLUKE tipe 115 harga murah, Hub : 089617332462
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgV37_ni755L0Vjzsz3MdVKaInAaLTBegVO-goErIV9ZWnj12USRXgh1wjBm_LHi_l6XU6zu_UtXaUpX2U5wDVOGs5vo30OJbjK_BPmO8EH3mtZstb2xqJWyU3SV91t036lbNhQNS-utUw/s1600/Multimeter+Fluke+115.jpg)
Designed by electricians. Engineered by Fluke.
For general purpose electrical and electronic test requirements, the
Fluke 115 true-rms digital multimeter provides the perfect answer. Its
simple operation, compact design and ease of use makes it perfect for
quick verifications and field service use.
The Fluke 115 displays true-rms voltage and current readings with
6000 count resolution, tests diodes, frequency, continuity and
capacitance and provides Min/Max/Average readings to record signal
fluctuations. A large white LED backlight aids work in poorly lit areas.
Its easy-open battery access door makes battery changes a snap.
Fluke 115 multimeters are independently tested for safe use in CAT III 600V environments.
And check out other members of the Fluke 110 family: the Fluke 113
Utility Multimeter, the Fluke 114 Electrical Multimeter, the Fluke 116
HVAC Multimeter and the Fluke 117 Commercial Electrician’s Multimeter.
Also check out the Fluke 114 Electrical
Multimeter, the Fluke 116 HVAC Multimeter with Temperature and
Microamps, and the Fluke 117, the Electrician’s Multimeter with
Non-contact voltage. |
|
|
|
|
| | | | | | | | |
Specifications |
Maximum voltage between any terminal and earth ground |
|
Surge protection |
|
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
|
Display |
Digital: |
6,000 counts, updates 4 per second |
|
Bar graph |
|
33 segments, updates 32 per second |
|
Operating Temperature |
|
Storage Temperature |
|
Battery type |
|
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery Life |
|
400 hours typical, without backlight |
|
Accuracy Specifications |
DC millivolts |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.00 V / 0.1 V |
Accuracy: |
± ([% of reading] + [counts]): 0.5% + 2 |
|
AC millivolts1 true-rms |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.0 V / 0.1 V |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity |
Range: |
600 Ω |
Resolution: |
1 Ω |
Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
|
Ohms |
Range/Resolution: |
600.0 Ω / 0.1 Ω |
Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
Accuracy: |
0.9 % + 1 |
Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
Accuracy: |
5 % + 2 |
|
Diode Test |
Range/Resolution: |
2.00 V / 0.001 V |
Accuracy: |
0.9% + 2 |
|
Capacitance |
Range/Resolution: |
1000 nF / 1 nF |
Range/Resolution: |
10.00 µF / 0.01 µF |
Range/Resolution: |
100.0 µF / 0.1 µF |
Range/Resolution: |
9999 µF / 1 µF |
Range/Resolution: |
100 µF to 1000 µF |
Accuracy: |
1.9% + 2 |
Range/Resolution: |
> 1000 µF |
Accuracy: |
5% + 20% |
|
Lo-Z Capacitance |
Range: |
1 nF to 500 µF |
Accuracy: |
10% + 2 typical |
|
AC amps true-rms (45 Hz to 500Hz) |
Range/Resolution: |
6.000 A / 0.001 A |
Range/Resolution: |
10.00 A / 0.01 A |
Accuracy: |
1.5% + 3 |
|
20 A overload for 30-seconds max |
|
DC amps |
Range/Resolution: |
6.000 A / 0.001 A |
Range/Resolution: |
10.00 A / 0.01 A |
Accuracy: |
1.0% + 3 |
|
20 A overload for 30-seconds max |
|
Hz (V or A input)2 |
Range/Resolution: |
99.99 Hz / 0.01 Hz |
Range/Resolution: |
999.9 Hz / 0.01 Hz |
Range/Resolution: |
9.999 kHz / 0.001 kHz |
Range/Resolution: |
50 kHz / 0.01 kHz |
Accuracy: |
0.1% + 2 |
|
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications |
Size |
|
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
|
Weight |
|
Warranty |
|
|
|
|
|
|
Untuk Pembelian dalam jumlah Banyak, Silakan Kontak Customer Service Kami untuk mendapatkan harga terbaik
HOTLINE Hubungi Kami di Contact
PENGIRIMAN dengan Kurir Terpercaya